The membrane Complies with BSEN ISO 140.
Acoustic Plasterboard complies fully with BS EN520 and is categorised as Types A, D.
Acoustic Plasterboard has a Thermal Conductivity figure of k = 0.24W/mK
Thermal Resistance:
12.5mm = 0.05m2 K/W
15.0mm = 0.06m2 K/W
See the Health & Safety Data Sheet HERE
See the Health & Safety Data sheet HERE
Technical Data
. Properties Values
Application temperature | +5°C to +40°C | ||
Service temperature | -10°C to +70°C | ||
Skinning time @ 20°C/65%RH | 5 minutes | ||
Cure rate | Time to full cure is dependent on sealant depth, ambient temperature and humidity. | ||
Chemical resistance | Fair resistance to most alkalis and dilute acids; poor resistance to hydrocarbon solvents. | ||
UV resistance | Not applicable | ||
Service life | 15 years + | ||
Movement accommodation | Butt joints (movement in tension and compression): 10% Lap joints (movement in shear): 20% | ||
Colours | White. |
Equipment
Our Acoustic Sealant is a one-part Fire Retardant Water-based Acrylic Sealant. It exhibits good adhesion to a wide variety of common building substrates without the need for a primer. Paintable with emulsion paint three hours after application. Allow 12 hours before overpainting with gloss paints.
When subject to flame our sealant will intumesce (expand and char), thus blocking the passage of fire and smoke.
Specification Compliances
BS EN ISO 11600 F 7.5P
BS 476 Part 20: 1987
Warres Report No: 23282, 9th March 1995
Warres Report No: 116997, 20th February 2001
Warres Report No: 119344, 12th July 2001
Warres Report No: 123325/A, 27th March 2002
Application Instructions
The joint surfaces must be clean, dry and free from all contamination. The surfaces should be degreased using a suitable cleaner.
Where applicable, appropriate joint filler e.g. our AMW or closed cell polyethylene foam, should be used to provide the correct joint depth (see chart under Technical Data for fire integrity and insulation achieved).
Our sealant is supplied in cartridges and can be applied into the joint using a Caulking Gun. All joint preparation, priming, and sealant application should be carried out in accordance with BS8000 Part 16, the British Standard for the sealing of joints in buildings using sealants.
Joint Size suitability
Minimum 6mm
Maximum 20mm (single application)
Minimum 10mm on porous substrates
Minimum 10mm on non-porous substrates
Maximum 20mm
Contact Technical Services. In general, joints should be as narrow as possible to prevent passage of fire.
Storage Life
12 months in original unopened package stored in a cool, dry place out of direct sunlight.
Avoid prolonged contact with the skin. If sealant cones into contact the eyes, flush with copious volumes of cold water and obtain medical attention. For further information consult Product Safety Data Sheet.
*Test incorporates seals and backing material on both faces of the construction.
Packaging: Polyethylene nozzles are included with each tube. Important: The information in this leaflet is given in good faith and based on results gained from experience and tests. However, all recommendations or suggestions are made without guarantee since the conditions of use are beyond our control. Goods are supplied subject to the Company’s terms and conditions of sales.